Arria II GX is an Altera FPGA family. Altera was part of Intel from 2015 until it became an independent company again in 2025, so the same parts also carry the Intel name.
This page lists 238 Arria II GX part numbers for 12 devices, from 42,959 to 244,188 logic elements. The device table below compares them, and each device then has its own list with package, speed grade, user I/O count and temperature range, and every part number links to its own page.
One part number names the device, the package, the speed grade and the temperature grade. Two part numbers that differ in a single character are different parts, so match the full number on your bill of materials.
For a field-by-field breakdown, open any part number below, for example EP2AGX45DF25I3.
Background: how to read an FPGA part number.
| Letter | Grade | Range | Part numbers |
|---|---|---|---|
| C | Commercial | 0°C to 85°C (TJ) | 144 |
| I | Industrial | -40°C to 100°C (TJ) | 94 |
| Device | Logic elements | Total RAM bits | Max user I/O | Packages | Speed grades | Temperature grades | Part numbers |
|---|---|---|---|---|---|---|---|
| EP2AGX45C | 42,959 | 3,517,440 | 156 | U17 (358-UBGA, FCBGA) | 3, 4, 5, 6 | C, I | 14 |
| EP2AGX45D | 42,959 | 3,517,440 | 364 | F25 (572-FBGA, FC), F29 (780-FBGA) | 3, 4, 5, 6 | C, I | 30 |
| EP2AGX65C | 60,214 | 5,371,904 | 156 | U17 (358-UBGA, FCBGA) | 3, 4, 5, 6 | C, I | 14 |
| EP2AGX65D | 60,214 | 5,371,904 | 364 | F25 (572-FBGA, FC), F29 (780-FBGA) | 3, 4, 5, 6 | C, I | 30 |
| EP2AGX95D | 89,178 | 6,839,296 | 260 | F25 (572-FBGA, FC) | 3, 4, 5, 6 | C, I | 15 |
| EP2AGX95E | 89,178 | 6,839,296 | 452 | F29 (780-FBGA), F35 (1152-FBGA) | 3, 4, 5, 6 | C, I | 30 |
| EP2AGX125D | 118,143 | 8,315,904 | 260 | F25 (572-FBGA, FC) | 3, 4, 5, 6 | C, I | 15 |
| EP2AGX125E | 118,143 | 8,315,904 | 452 | F29 (780-FBGA), F35 (1152-FBGA) | 3, 4, 5, 6 | C, I | 30 |
| EP2AGX190E | 181,165 | 10,177,536 | 372 | F29 (780-FBGA) | 3, 4, 5, 6 | C, I | 15 |
| EP2AGX190F | 181,165 | 10,177,536 | 612 | F35 (1152-FBGA) | 3, 4, 5, 6 | C, I | 15 |
| EP2AGX260E | 244,188 | 12,038,144 | 372 | F29 (780-FBGA) | 3, 4, 5, 6 | C, I | 15 |
| EP2AGX260F | 244,188 | 12,038,144 | 612 | F35 (1152-FBGA) | 3, 4, 5, 6 | C, I | 15 |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX45CU17I3G | 3 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX45CU17I3N | 3 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX45CU17C4 | 4 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX45CU17C4G | 4 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX45CU17C4N | 4 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX45CU17C5 | 5 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX45CU17C5G | 5 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX45CU17C5N | 5 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX45CU17I5 | 5 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX45CU17I5G | 5 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX45CU17I5N | 5 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX45CU17C6 | 6 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX45CU17C6G | 6 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX45CU17C6N | 6 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX45DF25I3 | 3 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX45DF25I3G | 3 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX45DF25I3N | 3 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX45DF25C4 | 4 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX45DF25C4G | 4 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX45DF25C4N | 4 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX45DF25C5 | 5 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX45DF25C5G | 5 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX45DF25C5N | 5 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX45DF25I5 | 5 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX45DF25I5G | 5 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX45DF25I5N | 5 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX45DF25C6 | 6 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX45DF25C6G | 6 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX45DF25C6N | 6 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX45DF29I3 | 3 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX45DF29I3G | 3 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX45DF29I3N | 3 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX45DF29C4 | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX45DF29C4G | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX45DF29C4N | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX45DF29C5 | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX45DF29C5G | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX45DF29C5N | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX45DF29I5 | 5 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX45DF29I5G | 5 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX45DF29I5N | 5 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX45DF29C6 | 6 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX45DF29C6G | 6 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX45DF29C6N | 6 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX65CU17I3G | 3 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX65CU17I3N | 3 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX65CU17C4 | 4 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX65CU17C4G | 4 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX65CU17C4N | 4 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX65CU17C5 | 5 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX65CU17C5G | 5 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX65CU17C5N | 5 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX65CU17I5 | 5 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX65CU17I5G | 5 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX65CU17I5N | 5 | 358-UBGA, FCBGA (17x17) | 156 | -40°C to 100°C (TJ) |
| EP2AGX65CU17C6 | 6 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX65CU17C6G | 6 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| EP2AGX65CU17C6N | 6 | 358-UBGA, FCBGA (17x17) | 156 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX65DF25I3 | 3 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX65DF25I3G | 3 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX65DF25I3N | 3 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX65DF25C4 | 4 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX65DF25C4G | 4 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX65DF25C4N | 4 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX65DF25C5 | 5 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX65DF25C5G | 5 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX65DF25C5N | 5 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX65DF25I5 | 5 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX65DF25I5G | 5 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX65DF25I5N | 5 | 572-FBGA, FC (25x25) | 252 | -40°C to 100°C (TJ) |
| EP2AGX65DF25C6 | 6 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX65DF25C6G | 6 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX65DF25C6N | 6 | 572-FBGA, FC (25x25) | 252 | 0°C to 85°C (TJ) |
| EP2AGX65DF29I3 | 3 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX65DF29I3G | 3 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX65DF29I3N | 3 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX65DF29C4 | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX65DF29C4G | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX65DF29C4N | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX65DF29C5 | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX65DF29C5G | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX65DF29C5N | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX65DF29I5 | 5 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX65DF29I5G | 5 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX65DF29I5N | 5 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2AGX65DF29C6 | 6 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX65DF29C6G | 6 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2AGX65DF29C6N | 6 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX95DF25I3 | 3 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX95DF25I3G | 3 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX95DF25I3N | 3 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX95DF25C4 | 4 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX95DF25C4G | 4 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX95DF25C4N | 4 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX95DF25C5 | 5 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX95DF25C5G | 5 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX95DF25C5N | 5 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX95DF25I5 | 5 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX95DF25I5G | 5 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX95DF25I5N | 5 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX95DF25C6 | 6 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX95DF25C6G | 6 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX95DF25C6N | 6 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX95EF29I3 | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX95EF29I3G | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX95EF29I3N | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX95EF29C4 | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX95EF29C4G | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX95EF29C4N | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX95EF29C5 | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX95EF29C5G | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX95EF29C5N | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX95EF29I5 | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX95EF29I5G | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX95EF29I5N | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX95EF29C6 | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX95EF29C6G | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX95EF29C6N | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX95EF35I3 | 3 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX95EF35I3G | 3 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX95EF35I3N | 3 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX95EF35C4 | 4 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX95EF35C4G | 4 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX95EF35C4N | 4 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX95EF35C5 | 5 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX95EF35C5G | 5 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX95EF35C5N | 5 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX95EF35I5 | 5 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX95EF35I5G | 5 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX95EF35I5N | 5 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX95EF35C6 | 6 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX95EF35C6G | 6 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX95EF35C6N | 6 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX125DF25I3 | 3 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX125DF25I3G | 3 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX125DF25I3N | 3 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX125DF25C4 | 4 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX125DF25C4G | 4 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX125DF25C4N | 4 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX125DF25C5 | 5 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX125DF25C5G | 5 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX125DF25C5N | 5 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX125DF25I5 | 5 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX125DF25I5G | 5 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX125DF25I5N | 5 | 572-FBGA, FC (25x25) | 260 | -40°C to 100°C (TJ) |
| EP2AGX125DF25C6 | 6 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX125DF25C6G | 6 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| EP2AGX125DF25C6N | 6 | 572-FBGA, FC (25x25) | 260 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX125EF29I3 | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX125EF29I3G | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX125EF29I3N | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX125EF29C4 | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX125EF29C4G | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX125EF29C4N | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX125EF29C5 | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX125EF29C5G | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX125EF29C5N | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX125EF29I5 | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX125EF29I5G | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX125EF29I5N | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX125EF29C6 | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX125EF29C6G | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX125EF29C6N | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX125EF35I3 | 3 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX125EF35I3G | 3 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX125EF35I3N | 3 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX125EF35C4 | 4 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX125EF35C4G | 4 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX125EF35C4N | 4 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX125EF35C5 | 5 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX125EF35C5G | 5 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX125EF35C5N | 5 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX125EF35I5 | 5 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX125EF35I5G | 5 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX125EF35I5N | 5 | 1152-FBGA (35x35) | 452 | -40°C to 100°C (TJ) |
| EP2AGX125EF35C6 | 6 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX125EF35C6G | 6 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| EP2AGX125EF35C6N | 6 | 1152-FBGA (35x35) | 452 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX190EF29I3 | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX190EF29I3G | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX190EF29I3N | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX190EF29C4 | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX190EF29C4G | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX190EF29C4N | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX190EF29C5 | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX190EF29C5G | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX190EF29C5N | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX190EF29I5 | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX190EF29I5G | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX190EF29I5N | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX190EF29C6 | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX190EF29C6G | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX190EF29C6N | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX190FF35I3 | 3 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX190FF35I3G | 3 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX190FF35I3N | 3 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX190FF35C4 | 4 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX190FF35C4G | 4 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX190FF35C4N | 4 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX190FF35C5 | 5 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX190FF35C5G | 5 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX190FF35C5N | 5 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX190FF35I5 | 5 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX190FF35I5G | 5 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX190FF35I5N | 5 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX190FF35C6 | 6 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX190FF35C6G | 6 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX190FF35C6N | 6 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX260EF29I3 | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX260EF29I3G | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX260EF29I3N | 3 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX260EF29C4 | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX260EF29C4G | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX260EF29C4N | 4 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX260EF29C5 | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX260EF29C5G | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX260EF29C5N | 5 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX260EF29I5 | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX260EF29I5G | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX260EF29I5N | 5 | 780-FBGA (29x29) | 372 | -40°C to 100°C (TJ) |
| EP2AGX260EF29C6 | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX260EF29C6G | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| EP2AGX260EF29C6N | 6 | 780-FBGA (29x29) | 372 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2AGX260FF35I3 | 3 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX260FF35I3G | 3 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX260FF35I3N | 3 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX260FF35C4 | 4 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX260FF35C4G | 4 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX260FF35C4N | 4 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX260FF35C5 | 5 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX260FF35C5G | 5 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX260FF35C5N | 5 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX260FF35I5 | 5 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX260FF35I5G | 5 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX260FF35I5N | 5 | 1152-FBGA (35x35) | 612 | -40°C to 100°C (TJ) |
| EP2AGX260FF35C6 | 6 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX260FF35C6G | 6 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
| EP2AGX260FF35C6N | 6 | 1152-FBGA (35x35) | 612 | 0°C to 85°C (TJ) |
Stratix 10Arria 10Cyclone 10 GXCyclone 10 LPMAX 10Stratix VArria VCyclone VStratix IVStratix IIIStratix II GXStratix IIStratix GXStratixArria II GZArria GXCyclone IV GXCyclone IV ECyclone III LSCyclone IIICyclone IICycloneFLEX 10KSFLEX 10KEFLEX 10KAFLEX 10KFLEX 8000FLEX 6000APEX 20KCAPEX 20KEAPEX 20KAPEX IIACEX 1KMercury