Stratix II GX is an Altera FPGA family. Altera was part of Intel from 2015 until it became an independent company again in 2025, so the same parts also carry the Intel name.
This page lists 103 Stratix II GX part numbers for 8 devices, from 33,880 to 132,540 logic elements. The device table below compares them, and each device then has its own list with package, speed grade, user I/O count and temperature range, and every part number links to its own page.
One part number names the device, the package, the speed grade and the temperature grade. Two part numbers that differ in a single character are different parts, so match the full number on your bill of materials.
For a field-by-field breakdown, open any part number below, for example EP2SGX30CF780C3.
Background: how to read an FPGA part number.
| Letter | Grade | Range | Part numbers |
|---|---|---|---|
| C | Commercial | 0°C to 85°C (TJ) | 70 |
| I | Industrial | -40°C to 100°C (TJ) | 33 |
| Device | Logic elements | Total RAM bits | Max user I/O | Packages | Speed grades | Temperature grades | Part numbers |
|---|---|---|---|---|---|---|---|
| EP2SGX30C | 33,880 | 1,369,728 | 361 | F780 (780-FBGA) | 3, 4, 5 | C, I | 14 |
| EP2SGX30D | 33,880 | 1,369,728 | 361 | F780 (780-FBGA) | 3, 4, 5 | C, I | 13 |
| EP2SGX60C | 60,440 | 2,544,192 | 364 | F484 (484-FBGA), F780 (780-FBGA) | 3, 4, 5 | C, I | 11 |
| EP2SGX60D | 60,440 | 2,544,192 | 364 | F780 (780-FBGA) | 3, 4, 5 | C, I | 13 |
| EP2SGX60E | 60,440 | 2,544,192 | 534 | F1152 (1152-FBGA) | 3, 4, 5 | C, I | 13 |
| EP2SGX90E | 90,960 | 4,520,448 | 558 | F1152 (1152-FBGA) | 3, 4, 5 | C, I | 13 |
| EP2SGX90F | 90,960 | 4,520,448 | 650 | F1508 (1508-FBGA, FC) | 3, 4, 5 | C, I | 13 |
| EP2SGX130G | 132,540 | 6,747,840 | 734 | F1508 (1508-FBGA, FC) | 3, 4, 5 | C, I | 13 |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2SGX30CF780C3 | 3 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30CF780C3G | 3 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30CF780C3N | 3 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30CF780I3 | 3 | 780-FBGA (29x29) | 361 | -40°C to 100°C (TJ) |
| EP2SGX30CF780I3N | 3 | 780-FBGA (29x29) | 361 | -40°C to 100°C (TJ) |
| EP2SGX30CF780C4 | 4 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30CF780C4G | 4 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30CF780C4N | 4 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30CF780I4 | 4 | 780-FBGA (29x29) | 361 | -40°C to 100°C (TJ) |
| EP2SGX30CF780I4N | 4 | 780-FBGA (29x29) | 361 | -40°C to 100°C (TJ) |
| EP2SGX30CF780C5 | 5 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30CF780C5G | 5 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30CF780C5N | 5 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30CF780I5N | 5 | 780-FBGA (29x29) | 361 | -40°C to 100°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2SGX30DF780C3 | 3 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30DF780C3G | 3 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30DF780C3N | 3 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30DF780I3N | 3 | 780-FBGA (29x29) | 361 | -40°C to 100°C (TJ) |
| EP2SGX30DF780C4 | 4 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30DF780C4G | 4 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30DF780C4N | 4 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30DF780I4 | 4 | 780-FBGA (29x29) | 361 | -40°C to 100°C (TJ) |
| EP2SGX30DF780I4G | 4 | 780-FBGA (29x29) | 361 | -40°C to 100°C (TJ) |
| EP2SGX30DF780I4N | 4 | 780-FBGA (29x29) | 361 | -40°C to 100°C (TJ) |
| EP2SGX30DF780C5 | 5 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30DF780C5G | 5 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| EP2SGX30DF780C5N | 5 | 780-FBGA (29x29) | 361 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2SGX60CF484I4 | 4 | 484-FBGA (23x23) | 291 | -40°C to 100°C (TJ) |
| EP2SGX60CF780C3 | 3 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60CF780C3G | 3 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60CF780C3N | 3 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60CF780C4 | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60CF780C4G | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60CF780C4N | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60CF780I4N | 4 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2SGX60CF780C5 | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60CF780C5G | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60CF780C5N | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2SGX60DF780C3G | 3 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60DF780C3N | 3 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60DF780I3N | 3 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2SGX60DF780C4 | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60DF780C4G | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60DF780C4N | 4 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60DF780I4 | 4 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2SGX60DF780I4G | 4 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2SGX60DF780I4N | 4 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| EP2SGX60DF780C5 | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60DF780C5G | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60DF780C5N | 5 | 780-FBGA (29x29) | 364 | 0°C to 85°C (TJ) |
| EP2SGX60DF780I5N | 5 | 780-FBGA (29x29) | 364 | -40°C to 100°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2SGX60EF1152C3 | 3 | 1152-FBGA (35x35) | 534 | 0°C to 85°C (TJ) |
| EP2SGX60EF1152C3G | 3 | 1152-FBGA (35x35) | 534 | 0°C to 85°C (TJ) |
| EP2SGX60EF1152C3N | 3 | 1152-FBGA (35x35) | 534 | 0°C to 85°C (TJ) |
| EP2SGX60EF1152I3N | 3 | 1152-FBGA (35x35) | 534 | -40°C to 100°C (TJ) |
| EP2SGX60EF1152C4 | 4 | 1152-FBGA (35x35) | 534 | 0°C to 85°C (TJ) |
| EP2SGX60EF1152C4G | 4 | 1152-FBGA (35x35) | 534 | 0°C to 85°C (TJ) |
| EP2SGX60EF1152C4N | 4 | 1152-FBGA (35x35) | 534 | 0°C to 85°C (TJ) |
| EP2SGX60EF1152I4 | 4 | 1152-FBGA (35x35) | 534 | -40°C to 100°C (TJ) |
| EP2SGX60EF1152I4G | 4 | 1152-FBGA (35x35) | 534 | -40°C to 100°C (TJ) |
| EP2SGX60EF1152I4N | 4 | 1152-FBGA (35x35) | 534 | -40°C to 100°C (TJ) |
| EP2SGX60EF1152C5 | 5 | 1152-FBGA (35x35) | 534 | 0°C to 85°C (TJ) |
| EP2SGX60EF1152C5G | 5 | 1152-FBGA (35x35) | 534 | 0°C to 85°C (TJ) |
| EP2SGX60EF1152C5N | 5 | 1152-FBGA (35x35) | 534 | 0°C to 85°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2SGX90EF1152C3 | 3 | 1152-FBGA (35x35) | 558 | 0°C to 85°C (TJ) |
| EP2SGX90EF1152C3G | 3 | 1152-FBGA (35x35) | 558 | 0°C to 85°C (TJ) |
| EP2SGX90EF1152C3N | 3 | 1152-FBGA (35x35) | 558 | 0°C to 85°C (TJ) |
| EP2SGX90EF1152C4 | 4 | 1152-FBGA (35x35) | 558 | 0°C to 85°C (TJ) |
| EP2SGX90EF1152C4G | 4 | 1152-FBGA (35x35) | 558 | 0°C to 85°C (TJ) |
| EP2SGX90EF1152C4N | 4 | 1152-FBGA (35x35) | 558 | 0°C to 85°C (TJ) |
| EP2SGX90EF1152I4 | 4 | 1152-FBGA (35x35) | 558 | -40°C to 100°C (TJ) |
| EP2SGX90EF1152I4G | 4 | 1152-FBGA (35x35) | 558 | -40°C to 100°C (TJ) |
| EP2SGX90EF1152I4N | 4 | 1152-FBGA (35x35) | 558 | -40°C to 100°C (TJ) |
| EP2SGX90EF1152C5 | 5 | 1152-FBGA (35x35) | 558 | 0°C to 85°C (TJ) |
| EP2SGX90EF1152C5G | 5 | 1152-FBGA (35x35) | 558 | 0°C to 85°C (TJ) |
| EP2SGX90EF1152C5N | 5 | 1152-FBGA (35x35) | 558 | 0°C to 85°C (TJ) |
| EP2SGX90EF1152I5N | 5 | 1152-FBGA (35x35) | 558 | -40°C to 100°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2SGX90FF1508C3 | 3 | 1508-FBGA, FC (40x40) | 650 | 0°C to 85°C (TJ) |
| EP2SGX90FF1508C3G | 3 | 1508-FBGA, FC (40x40) | 650 | 0°C to 85°C (TJ) |
| EP2SGX90FF1508C3N | 3 | 1508-FBGA, FC (40x40) | 650 | 0°C to 85°C (TJ) |
| EP2SGX90FF1508I3N | 3 | 1508-FBGA, FC (40x40) | 650 | -40°C to 100°C (TJ) |
| EP2SGX90FF1508C4 | 4 | 1508-FBGA, FC (40x40) | 650 | 0°C to 85°C (TJ) |
| EP2SGX90FF1508C4G | 4 | 1508-FBGA, FC (40x40) | 650 | 0°C to 85°C (TJ) |
| EP2SGX90FF1508C4N | 4 | 1508-FBGA, FC (40x40) | 650 | 0°C to 85°C (TJ) |
| EP2SGX90FF1508I4 | 4 | 1508-FBGA, FC (40x40) | 650 | -40°C to 100°C (TJ) |
| EP2SGX90FF1508I4G | 4 | 1508-FBGA, FC (40x40) | 650 | -40°C to 100°C (TJ) |
| EP2SGX90FF1508I4N | 4 | 1508-FBGA, FC (40x40) | 650 | -40°C to 100°C (TJ) |
| EP2SGX90FF1508C5G | 5 | 1508-FBGA, FC (40x40) | 650 | 0°C to 85°C (TJ) |
| EP2SGX90FF1508C5N | 5 | 1508-FBGA, FC (40x40) | 650 | 0°C to 85°C (TJ) |
| EP2SGX90FF1508I5N | 5 | 1508-FBGA, FC (40x40) | 650 | -40°C to 100°C (TJ) |
| Part number | Speed grade | Package | User I/O | Temperature |
|---|---|---|---|---|
| EP2SGX130GF1508C3 | 3 | 1508-FBGA, FC (40x40) | 734 | 0°C to 85°C (TJ) |
| EP2SGX130GF1508C3G | 3 | 1508-FBGA, FC (40x40) | 734 | 0°C to 85°C (TJ) |
| EP2SGX130GF1508C3N | 3 | 1508-FBGA, FC (40x40) | 734 | 0°C to 85°C (TJ) |
| EP2SGX130GF1508I3 | 3 | 1508-FBGA, FC (40x40) | 734 | -40°C to 100°C (TJ) |
| EP2SGX130GF1508C4 | 4 | 1508-FBGA, FC (40x40) | 734 | 0°C to 85°C (TJ) |
| EP2SGX130GF1508C4G | 4 | 1508-FBGA, FC (40x40) | 734 | 0°C to 85°C (TJ) |
| EP2SGX130GF1508C4N | 4 | 1508-FBGA, FC (40x40) | 734 | 0°C to 85°C (TJ) |
| EP2SGX130GF1508I4 | 4 | 1508-FBGA, FC (40x40) | 734 | -40°C to 100°C (TJ) |
| EP2SGX130GF1508I4G | 4 | 1508-FBGA, FC (40x40) | 734 | -40°C to 100°C (TJ) |
| EP2SGX130GF1508I4N | 4 | 1508-FBGA, FC (40x40) | 734 | -40°C to 100°C (TJ) |
| EP2SGX130GF1508C5 | 5 | 1508-FBGA, FC (40x40) | 734 | 0°C to 85°C (TJ) |
| EP2SGX130GF1508C5G | 5 | 1508-FBGA, FC (40x40) | 734 | 0°C to 85°C (TJ) |
| EP2SGX130GF1508C5N | 5 | 1508-FBGA, FC (40x40) | 734 | 0°C to 85°C (TJ) |
Stratix 10Arria 10Cyclone 10 GXCyclone 10 LPMAX 10Stratix VArria VCyclone VStratix IVStratix IIIStratix IIStratix GXStratixArria II GZArria II GXArria GXCyclone IV GXCyclone IV ECyclone III LSCyclone IIICyclone IICycloneFLEX 10KSFLEX 10KEFLEX 10KAFLEX 10KFLEX 8000FLEX 6000APEX 20KCAPEX 20KEAPEX 20KAPEX IIACEX 1KMercury